Search results for "Spectral purity"
showing 7 items of 7 documents
SINGLE-PEAK RESOLUTION CRITERIA FOR OPTIMIZATION OF MOBILE PHASE COMPOSITION IN LIQUID CHROMATOGRAPHY
2001
Three criteria that evaluate the single peak resolution (peak purity) in chromatography, the free height fraction, free area fraction, and valley ratio, are examined. The main advantages of these criteria against other criteria based on peak pair separation, are that the measurements are not affected by the identity of neighboring peaks and are normalized, which make them very intuitive. The methodology is illustrated through the isocratic separation of mixtures of several sulphonamides (sulphacetamide, sulphadiazine, sulphadimethoxine, sulphaguanidine, sulphamerazine, sulphamethazine, sulphamethoxazole, sulphamethizole, sulphamonomethoxine, sulphanilamide, sulphapyridine, sulphaquinoxaline…
Robust interpretive optimisation in high-performance liquid chromatography considering uncertainties in peak position.
2005
In the context of interpretive chromatographic optimisation, robustness is usually calculated by introducing deliberated shifts in the nominal optimal conditions and evaluating their effects on the monitored objective function, mimicking thus the experimental procedures used in method validation. However, such strategy ignores a major source of error: the uncertainties associated to the modelling step, that may give rise to deceiving results when conditions that were expected to yield baseline separation are reproduced in the chromatograph. Two approaches, based on the peak purity concept, are here proposed to evaluate the robustness of the objective function under the perspective of measur…
Limits of multi-linear gradient optimisation in reversed-phase liquid chromatography
2005
Abstract The concept of limiting peak purity was applied to quantify the degree of completion of the separation capability of a chromatographic system using multi-linear gradients. The objective was to check whether the complexity of a gradient program deserves be increased to enhance resolution by inserting more linear segments, or on the contrary, no significant improvements can be expected under more complex gradients. A set of 19 isoindole derivatives of primary amino acids was selected to test the performance of isocratic, single linear and multi-linear gradients. Accurate simulated chromatograms were obtained via numerical integration of the general equation of gradient elution, using…
Considerations on the modelling and optimisation of resolution of ionisable compounds in extended pH-range columns
2005
Abstract The problems associated to the modelling and optimisation of the chromatographic resolution of mixtures involving ionisable solutes at varying pH and acetonitrile content are discussed. Several retention models that separate the contributions of solute, column and stationary phase, were used. The retention was predicted with low errors in large pH domains (2–12), which was an essential requirement to face the optimisation of resolution. The selected mixture was particularly problematic under the viewpoint of resolution, owing to the excessively diverse acid–base behaviour of solutes. This variety led to sudden drops in retention at different pH for each solute, yielding numerous pe…
Narrow linewidth operation of the RILIS titanium: Sapphire laser at ISOLDE/CERN
2013
Abstract A narrow linewidth operating mode for the Ti:sapphire laser of the CERN ISOLDE Resonance Ionization Laser Ion Source (RILIS) has been developed. This satisfies the laser requirements for the programme of in-source resonance ionization spectroscopy measurements and improves the selectivity for isomer separation using RILIS. A linewidth reduction from typically 10 GHz down to 1 GHz was achieved by the intra-cavity insertion of a second (thick) Fabry-Perot etalon. Reliable operation during a laser scan was achieved through motorized control of the tilt angle of each etalon. A scanning, stabilization and mode cleaning procedure was developed and implemented in LabVIEW. The narrow linew…
Enhanced calculation of optimal gradient programs in reversed-phase liquid chromatography
2003
Abstract The resolution of a mixture of 16 β-blockers under gradient elution was optimised using both isocratic and gradient training sets, with a reversed-phase column and acetonitrile–water eluents. Error theory was applied to measure the information extracted from different gradient experimental designs. This allows checking the expected accuracy when gradient predictions exceed the initial solvent concentrations tested in the training set. This work applies the results on modelling found in a previous study [J. Chromatogr. A 1018 (2003) 169] where the performance of several retention models was compared. Enhanced retention predictions were applied to the optimisation of gradient program…
Constraining the pass-band of future space-based coronagraphs for observations of solar eruptions in the FeXIV 530.3 nm “green line”
2017
This research has received funding from the European Research Council (ERC) under the European Union’s Horizon 2020 research and innovation programme (grant agreement No 647214) and from the UK Science and Technology Facilities Council. Observations of the solar corona in the FeXIV 530.3 nm “green line” have been very important in the past, and are planned for future coronagraphs on-board forthcoming space missions such as PROBA-3 and Aditya. For these instruments, a very important parameter to be optimized is the spectral width of the band-pass filter to be centred over the “green line”. Focusing on solar eruptions, motions occurring along the line of sight will Doppler shift the line prof…